Capital Vstar (Siemens) - vulnerabilities (CVEs)
14 CVEs, 0 in the last 30 days, 2 known versions, newest CVE from 2021-11-09. Vendor: Siemens.
CVEs of Capital Vstar
- CVE-2021-31882 - CVSS 7.5 (high), 2021-11-09: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). The DHCP…
- CVE-2021-31889 - CVSS 9.1 (critical), 2021-11-09: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303),…
- CVE-2021-31344 - CVSS 6.9 (medium), 2021-11-09: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303),…
- CVE-2021-31881 - CVSS 7.5 (high), 2021-11-09: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When…
- CVE-2021-31885 - CVSS 7.5 (high), 2021-11-09: A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All…
- CVE-2021-31346 - CVSS 9.1 (critical), 2021-11-09: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303),…
- CVE-2021-31883 - CVSS 7.5 (high), 2021-11-09: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When…
- CVE-2021-31890 - CVSS 9.1 (critical), 2021-11-09: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303),…
- CVE-2021-31884 - CVSS 9.8 (critical), 2021-11-09: A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All…
- CVE-2021-31345 - CVSS 9.1 (critical), 2021-11-09: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303),…
- CVE-2021-25664 - CVSS 8.7 (high), 2021-04-22: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus…
- CVE-2021-25663 - CVSS 8.7 (high), 2021-04-22: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus…
- CVE-2020-28388 - CVSS 6.5 (medium), 2021-02-09: A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE…
- CVE-2019-13939 - CVSS 7.1 (high), 2020-01-16: A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions < V2.8.2), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC…