CVE-2024-30189
A vulnerability has been identified in SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0) (All versions), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0) (All versions), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0) (All versions), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0) (All versions), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0) (All versions), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0) (All versions), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6) (All versions), SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0) (All versions), SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6) (All versions), SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0) (All versions), SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0) (All versions), SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0) (All versions), SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0) (All versions), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0) (All versions), SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0) (All versions), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0) (All versions), SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0) (All versions), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0) (All versions), SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0) (All versions), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0) (All versions), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6) (All versions), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0) (All versions), SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0) (All versions), SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6) (All versions), SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0) (All versions), SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0) (All versions), SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0) (All versions), SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0) (All versions), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0) (All versions), SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0) (All versions), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0) (All versions), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0) (All versions), SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0) (All versions), SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0) (All versions), SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0) (All versions), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0) (All versions), SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0) (All versions), SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0) (All versions), SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0) (All versions), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0) (All versions), SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0) (All versions), SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0) (All versions), SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0) (All versions), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0) (All versions), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0) (All versions), SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0) (All versions), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0) (All versions), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0) (All versions), SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) (All versions). This CVE refers to Scenario 1 "Leak frames from the Wi-Fi queue" of CVE-2022-47522. Affected devices queue frames in order to subsequently change the security context and leak the queued frames. This could allow a physically proximate attacker to intercept (possibly cleartext) target-destined frames.
- Score
- CVSS 3.1 6.1 Medium
- Status
- Deferred - productcert@siemens.com
- Published
- 2024-04-09
- Last modified
- 2024-08-02
- Weaknesses
- CWE-290
Affected products
- Scalance W721-1 Rj45 (Siemens)
- Scalance W722-1 Rj45 (Siemens)
- Scalance W734-1 Rj45 (Siemens)
- Scalance W734-1 Rj45 Usa (Siemens)
- Scalance W738-1 M12 (Siemens)
- Scalance W748-1 M12 (Siemens)
- Scalance W748-1 Rj45 (Siemens)
- Scalance W761-1 Rj45 (Siemens)
- Scalance W774-1 M12 Eec (Siemens)
- Scalance W774-1 Rj45 (Siemens)
- Scalance W774-1 Rj45 Usa (Siemens)
- Scalance W778-1 M12 (Siemens)
- Scalance W778-1 M12 Eec (Siemens)
- Scalance W778-1 M12 Eec Usa (Siemens)
- Scalance W786-1 Rj45 (Siemens)
- Scalance W786-2 Rj45 (Siemens)
- Scalance W786-2 Sfp (Siemens)
- Scalance W786-2ia Rj45 (Siemens)
- Scalance W788-1 M12 (Siemens)
- Scalance W788-1 Rj45 (Siemens)
- Scalance W788-2 M12 (Siemens)
- Scalance W788-2 M12 Eec (Siemens)
- Scalance W788-2 Rj45 (Siemens)
References