CVE-2017-6780
A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart, aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed, the system will restart, creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System, if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director, if running a software release prior to IoT-FND Release 4.0. Cisco Bug IDs: CSCvc77164.
- Score
- CVSS 3.0 7.5 High
- Status
- Modified - psirt@cisco.com
- Published
- 2017-09-07
- Last modified
- 2024-08-05
- Weaknesses
- CWE-399, CWE-770
Affected products
References
- http://www.securityfocus.com/bid/100641
- https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170906-fnd