CVE-2013-2780
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
- Score
- CVSS 2.0 7.8 High
- Status
- Modified - ics-cert@hq.dhs.gov
- Published
- 2013-04-22
- Last modified
- 2024-08-06
Affected products
- Simatic S7-1200 Cpu 1211c Firmware (Siemens)
- Simatic S7-1200 Cpu 1212c Firmware (Siemens)
- Simatic S7-1200 Cpu 1212fc Firmware (Siemens)
- Simatic S7-1200 Cpu 1214 Fc Firmware (Siemens)
- Simatic S7-1200 Cpu 1214c Firmware (Siemens)
- Simatic S7-1200 Cpu 1215 Fc Firmware (Siemens)
- Simatic S7-1200 Cpu 1215c Firmware (Siemens)
- Simatic S7-1200 Cpu 1217c Firmware (Siemens)
- Simatic S7-1200 Firmware (Siemens)
References
- http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf